PUBLICATIONS

Abstract

Evaluation of Linear Array Human Papillomavirus Genotyping Using Automatic Optical Imaging Software.


Jeronimo J, Wentzensen N, Long R, Schiffman M, Dunst ST, Allen RA, Walker JL, Gold MA, Zuna RE, Sherman ME, Wacholder S, Wang SS

J Clin Microbiol. 2008 Aug;46(8):2759-65. Epub 2008 Jun 11

Abstract:

Variations in biological behavior suggest that each carcinogenic human papillomavirus (HPV) type should be considered individually in etiologic studies. HPV genotyping assays might have clinical applications if they are approved for use by the FDA. A widely used genotyping assay is the Roche Linear Array HPV genotyping test (LA). We used LA to genotype the HPV isolates from cervical specimens from women with the full spectrum of cervical disease: cervical cancer, cervical intraepithelial neoplasia (CIN), and HPV infections. To explore the feasibility and value of the automated reading of the LA results, we custom-designed novel, optical imaging software that provides optical density measurements of LA bands. We compared unmagnified visual examination with the automated measurements. The two measurements were highly associated. By either method, the threshold between a negative and a positive result was fairly sharp, with a clear bimodal distribution. Visually, most positive results were judged to be strong or medium, with fewer equivocal results categorized as weak (9.5% of positive samples), very weak (6.5% of positive samples), or extremely weak (7.7% of positive samples). The automated measurements of the intensities were significantly associated with the strength of the visual categories (P < 0.001). At the extremes of the automated signal intensities ( < or = 20 units or > or = 120 units), the bands were almost always categorized visually as negative and positive, respectively. In the equivocal zone (20 to 119 units), specimens were more increasingly likely to be judged to be visually positive as the number of other, definite infections on the same strip increased (P for trend < 0.001). Multiple, concurrent infections comprise > or = 25% of HPV infections; thus, any systematic visual tendency that influences their evaluation when the result is equivocal should be minimized. Therefore, automated reading is probably worth development if easy-to-calibrate hardware and software can be optimized.


Jeronimo J, Wentzensen N, Long R, Schiffman M, Dunst ST, Allen RA, Walker JL, Gold MA, Zuna RE, Sherman ME, Wacholder S, Wang SS. Evaluation of Linear Array Human Papillomavirus Genotyping Using Automatic Optical Imaging Software. 
J Clin Microbiol. 2008 Aug;46(8):2759-65. Epub 2008 Jun 11

PMID | PMCID